Shopping: Real Estate |  Costumes  |  Guitars
This Issue Archived Articles Blog About Us Contact Us
SEARCH


A New Home Workshop, Part 7

Electricals

By Julian Edgar

Click on pics to view larger images

At a glance...

  • Power
  • Lights
  • Fan
  • Heaters
  • Wiring
Email a friend     Print article

In a workshop – home or otherwise – the efficient layout of the power and light is of great importance. Here’s how it was done.

Power

After considering carefully the potential internal layouts within the 12 x 8 metre space, and so the required location of power-points, I decided on the following approach:

·       12 double power-points mounted around the walls at waist level

·       One floor-level power-point for a rainwater pump

·       One 15-amp power-point, positioned high on a wall for a hoist

·       Five hanging power-points, suspended from the roof

·       One single weatherproof power-point mounted on the outside wall of the shed

The internal double power-points are not distributed evenly around the periphery of the shed but instead are located more densely where machine tools will be placed.  

The wall power points are mounted on rectangular pieces of polypropylene (cut up kitchen chopping board) screwed to the top hat girts.

Click for larger image

The hanging power-points (that experience shows will be among the most frequently used of all the power-points) are expensive but very useful. Suspended on long chains, they avoid the requirement for extension cords to run across the floor and are easily accessible, even with a lot of stuff mounted against the walls of the shed. They are placed 200cm above floor level – high enough not to be walked into, but still low enough to be easily reached.

The wall-mounted power-points are wired in two circuits, each protected by a 20 amp combined safety switch circuit breaker (RCD / MCB).  The 15 amp power point has its own 16 amp safety switch circuit breaker. The external and hanging power points are wired into another 20 amp breaker. This gives four power circuits, each with its own RCD / MCB.

All power wiring is in 2.5 square millimetre copper cable.

Lights

In my previous 14 x 6 metre home workshop, I used 12 suspended HID lights, each running a 150W metal halide globe. These were switched in two groups of six. The choice of these lights was made after experimenting with a variety of light sources.

In addition, I used three suspended 48W compact fluorescent lights – these were used when instant illumination was required (the HID lights take some time to come up to full brilliance), and when less intense illumination was needed (like when I just wanted to get something from the shed at night).

Click for larger image

This approach worked extremely well, the HID lights giving a measured illumination of over 500 lux right through the workshop. I therefore decided to use a similar approach with the new workshop – that was easy to do, as when I moved house, I kept all the HID lights!

This time, for the lower level lighting, I went for two 20W compact fluorescents that feature inbuilt diffusers.

In addition, I placed a twin 500W externally mounted floodlight aimed at the yard.

The HID lights, wired into place with 2.5 square millimetre cable, run circuit protection comprising a 16 amp RCD / MCB.  These lights are switched in two banks of six.

The internal compact fluorescents, and the external floodlight, are connected with 1.5 square millimetre cable and are operated via two switches. These are wired to a single 10 amp RCD / MCB.

Heaters

Where I live it gets (for Australia at least) cold in winter. However, it is difficult to heat such a large volume (around 500 cubic metres) that lacks any kind of insulation. So I chose to not heat the volume, but to heat only me.

Click for larger image

To do this, I used three suspended radiant heaters. These are each 2.2kW, three-bar designs that I picked up for $20 each at a second-hand shop.  With a good clean (requiring disassembly), the reflectors came up beautifully and with a 2.2kW output (over double a conventional single bar radiator) they pump out plenty of heat.

The heaters, suspended 2.3 metres above the floor, are mounted as follows:

·       One located ahead of where the hoist is expected to go (the logic being that I intend spending lots of time working in engine bays and around the front of cars)

·       One mounted over my work bench, and another over my welding bench

A fourth I decided to keep as a portable heater – the idea is to mount it on a solid, tall stand so that it can be moved around as necessary.

The heaters are wired into place with separate runs of 2.5 square millimetre cable, and are switched with three switches. They are wired to three 16 amp RCD / MCB units.

Fan

Click for larger image

I mounted a large oscillating fan high on one wall. This is fed power from a socket switched from the main board. The socket is wired into place with 1.5 square millimetre cable.

Main Board

Click for larger image

The circuit breaker board, all the switches and one of the double power points are mounted on a single piece of thick plywood located next to the personal access door. This makes it easy to switch everything off as you leave the workshop.

From left to right, the switches are for:

-       Three suspended heaters

-       Outside floodlight and inside fan

-       High intensity discharge lights

-       Compact fluorescents

The plywood panel is hinged on one side, allowing it to be swung open for wiring changes.

Shopping list

If you have been keeping count, you will have noticed that the shopping list for the electrics is certainly adding –up.  Thirteen double power points, nine circuit breakers, five hanging power points, hundreds of metres of cabling…

I estimate that at my local hardware store, the bill for parts alone would have been something like AUD$3,000. However, I paid about one-third of this by taking two approaches:

·       Buying goods second hand. For example, the powerful exterior floodlight was bought at a garage sale for $20 and needed only to be mounted on a bracket.

·       Watching eBay for people selling off new bits left over after a major job (the five hanging power points), and for low cost lighting (the two 20W compact fluorescents)

·       Buying most of the stuff (power points, conduit, cable, etc) from an electrical wholesaler.  I used Kalmarc Electrical Industries, Unit 3 / 191 The Horsley Drive, Fairfield NSW 2165, phone 02 9726 3111. To give you an idea of price relativity, from this wholesaler a length of conduit was about 25 per cent of the cost being charged by my local hardware store. That certainly made the 450km round trip to the wholesaler worthwhile!

The main parts used in wiring the workshop are shown in the following table.

No.

Item

Comments

13

Double power points

12 wall mounted + 1 for pump at ground level

1

15 amp single power point

High mounted for hoist

5

Hanging power points

Suspended from roof 2m above floor

1

External weatherproof single power point

1

Single gang switch

For compact fluorescent lights

2

2-gang switches

For individual control of outside floodlight and inside fan, and control of two banks of HID lights

1

3-gang switch

For individual control of suspended heaters

17

35mm deep mounting blocks

For mounting of power points and switches

14

Non-switched surface mount sockets plus bases

Allowing plug-in of HID lights, fan & external light

10

Ceiling roses

For wiring heaters,  compact fluorescents and hanging power points

2

Inline bayonet light sockets

For suspended compact fluorescents

1

Single pole RCD MCB 10 amp

For external floodlight,  internal compact fluorescents and fan

3

single pole RCD MCB 20 amp

For power point circuits

5

Single pole RCD MCB 16 amp

For 15 amp power point, heaters, HID lights

1

18 pole surface mount enclosure

Shed sub-board

1

1 pole main switch 63 amp

Main on/off for shed sub-board

3

3 x 100 metre rolls 2.5mm earth plus twin cable

Used for all power point circuits and HID lighting circuits

1

100 metre roll 1.5mm earth plus twin cable

Used for external floodlight, fan and internal compact fluorescents

2

15 metre, 15 amp ‘caravan’ extension cables

Used to form the feeds for the hanging power points, heaters and fluorescent lights. (Cheaper to buy as extension cables than bare cable!)

1

25 metre roll 25mm corrugated conduit

Used to form bends between hard sections of conduit

30

4 metre lengths 25mm conduit grey

Large amount used as all wiring in shed run in conduit

130

25mm conduit joiners

Large number used as these work in conjunction with flex conduit to form bends

150

25mm half saddle conduit clamps

200

Assorted self-drilling fasteners

 

2

20 watt compact fluorescents

 

12

150W HID lights

Previously purchased second hand and then equipped with new bulbs

3

2.2kW suspended electric radiator heaters

Purchased second hand and then overhauled

1

Twin 500W exterior floodlight

Purchased second hand and then matched to new mounting bracket

1

Fan

Wall mounted oscillating

Installation

Click for larger image

A major issue with wiring such a tall shed is access.

The conduit runs on the walls could be done using a tall extension ladder, but the roof wiring required the hiring of a 4 metre scaffold – it was simply too dangerous to work on a ladder when you needed both hands free.  The hire of this scaffold cost $360. Note that the disassembled scaffold can easily be fitted on a normal car trailer (pictured).

The wiring took many hours to complete but didn’t require any cash outlay. (Of course, here in Australia, wiring should always be supervised by a licensed electrician.)

Conclusion

In terms of time and cost, the electricals formed a major component of the total workshop effort. However, the ease of use of the workshop, and the ability to work at night, make it worthwhile!

Pluses:  Great lighting and power distribution; adequate heating and cooling

Minuses: It takes a long time to do cable and conduit runs when working high on a scaffold.

The Surprise: Shop around and save 75 per cent in electrical parts prices!

Cost:

Parts - $1300

Scaffold hire - $360

Next issue: a unique solution for storage

The parts in this series:

Part 1 - Clearing the space

Part 2 - Planning the design

Part 3 - Gaining planning authority approval

Part 4 - The concrete slab

Part 5 - Getting the shed erected

Part 6 - Stormwater handling

Part 7 - The electricals

Part 8 - Organising storage

Part 9 - Building the workbenches

Part 10 - Evaluating the outcome

Interested in home workshop projects and techniques? You’re sure then to be interested in the Home Workshop Sourcebook, available now.

Did you enjoy this article?

Please consider supporting AutoSpeed with a small contribution. More Info...


Share this Article: 

More of our most popular articles.
Using a multimeter

DIY Tech Features - 6 January, 2009

How to Electronically Modify Your Car, Part 4

A forgotten Japanese classic

Special Features - 6 January, 2009

Mitsubishi Colt Fastback

An aerodynamic undertray - that didn't work!

DIY Tech Features - 28 October, 2008

Trialling a Rear Undertray

(Relatively) budget mods to a Skyline GT-R

DIY Tech Features - 1 December, 2009

GT-R Revisited

Modifying the regen braking system on a Toyota Prius

DIY Tech Features - 15 December, 2004

A World First: Modifying Regen Braking

Stopping the heat spreading

DIY Tech Features - 1 July, 2014

Making turbo heat shields

Finding the best fuel for cars of the future - the real answers

Technical Features - 18 March, 2008

Assessing the Alternatives

There are good technical reasons why steam could return

Technical Features - 9 October, 2007

Alternative Cars, Part 5 - Steam

So what's detonation and how can it be detected?

DIY Tech Features - 2 November, 1999

DIY Detonation Detection Part 1

Almost beyond belief in its brilliance

Special Features - 12 May, 2009

The Amazing Tesla

Copyright © 1996-2020 Web Publications Pty Limited. All Rights ReservedRSS|Privacy policy|Advertise
Consulting Services: Magento Experts|Technologies : Magento Extensions|ReadytoShip